Mustek Inverter MUST PV19-4024 EXP, 4kW, 1-phase, 24V, 100A MPPT, 500V

Product image of Mustek PV19-4024EXP
  • Product image of Mustek PV19-4024EXP 1

Pildid on illustratiivsed. Nendel kujutatud toode võib erineda pakutavast või sisaldada tootekomplekti mittekuuluvaid osiseid.

VendorMustek
Product codePV19-4024EXP
Price€561.00
Price (excl. VAT)€459.84
Delivery5-7 workdays
Quantity 3  pcs
TransportFREE IN ESTONIA!
ESTO
Telia
LHV

ESTO financing calculator

NB! Järelmaks on finantskohustus,
millega kaasnevad kulud. Tutvu tingimustega siin.

Telia financing calculator

NB! Järelmaks on finantskohustus,
millega kaasnevad kulud. Tutvu tingimustega siin.

LHV financing calculator

NB! Järelmaks on finantskohustus,
millega kaasnevad kulud. Tutvu tingimustega siin.

Solar inverter MUST PV19-4024 EXP, 4kW, 1-phase, for 24V battery, PV max. 100A/ 500V/ 5kW  Features: Multifunction inverter/charger, combining functions of inverter, MPPT 100A solar charger and battery charger to offer uninterruptible power support with portable size. No battery is required for this inverter. The LCD display allows you to set operating parameters and charger priorities. Rated power 4kW. Solar panels power up to 5kW. The maximum PV open circuit voltage is 500V DC and the MPPT voltage is 150~450V DC, allowing full use of solar energy. Parallel operation not supported. Integrated MPPT PV charge controller. Combination power supply from solar, AC or battery to ensure continuous power supply. Flexibly schedule the inverter charging and discharging time.
 Technical specifications: Battery voltage: 24V DC. Rated power: 4000W. Surge power: 8000VA. Waveform: pure sine wave. Battery type: lithium. Transfer time: 10ms/20ms. Frequency: 50/60Hz. PV array open circuit voltage max: 500V DC. MPPT voltage range: 150~450V DC. Max. solar charge current: 100A. PV array power max: 5000W. Display: LCD. Operating temperature: 0°C~+55°C. Dimensions: 322x486x134 mm. Weight: 11kg. Certificates: CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011); EN IEC62368-1:2020+A11:2020; CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011); EN IEC62368-1:2018, EN IEC62109-1:2010, EN IEC62109-2:2011.
 Specifications
Nominal battery system voltage24V DC
Inverter output
Rated power4000VA / 4000W
Surge power8000VA
Waveformpure sine wave
AC voltage regulation (Battery mode)230V AC +/- 5% @ 50/60Hz
Transfer time10ms (UPS/VDE4105) / 20ms (APL)
Inverter efficiency (peak)92%
AC input
Voltage230V AC
Selectable voltage range170~280V AC (UPS) / 90~280V AC (APL) / 184~253VAC (VED4105)
Frequency range50Hz / 60Hz (Auto sensing)
Battery
Normal voltage24V DC
Floating charge voltage27.4V DC
Overcharge protection30V DC
Solar charger AC charger
Maximum PV array open circuit voltage500V DC
MPPT range @ operating voltage150~450V DC
Maximum solar charge current100A
Maximum PV array power5000W
Maximum AC charge current80A
Maximum charge current100A
General specifications
Dimensions(W*H*D)322*486*134 mm
Net weight11.5 kg
Altitude 2000m
Operating temperature0°C to 55°C
Humidity range (non-condensing)5% - 95%
Storage temperature-15°C to 60°C

 Warranty:  The warranty of the voltage converter (inverter) is valid from the day when we (the seller) is provided with the serial number of the inverter, the purchase invoice, a certified electrician's certificate about the installed: 1) Lightning protection and overvoltage limiter (on the input side) 2) Lightning protection (between solar panels and inverter) 3) DC voltage switch between panels and inverter 4) Dedicate grounding for solar panels separated from grounding of the house
 The 2-year (24-month) manufacturer's warranty begins from the day of purchase, but comes into effect only after submission of these documents. Note: Lightning strike is not a valid warranty claim, it is classified as insurance claim.
 

Send link to friend